Skip to content
TR EN
Get a Quote 0424 236 25 40

Load-Bearing ElementsProducts

Precast Column

A precast column is a vertical reinforced concrete member produced in the plant and set into its foundation on site. It carries beam and roof loads down to the foundations and forms the structural frame of an industrial building.

Precast Column

What is a precast column?

A precast column is a vertical reinforced concrete member cast in a controlled plant environment, delivered to site ready to install and set into its foundation. In precast buildings, columns collect the loads coming from roof girders, beams and gutter beams and carry them down to the foundations.

Its role in an industrial building

In single-story factories and warehouses, columns are the main members resisting both vertical loads and lateral actions such as wind and earthquakes. They are typically fixed rigidly into the foundation, while the beams resting on them are usually connected with pinned joints. As a result, the column section, its reinforcement and its foundation connection directly govern how the building performs in an earthquake.

Sections and details

Precast columns are most often produced with square or rectangular sections. Depending on the project, a column may include:

  • Corbels supporting beams, roof girders or crane beams
  • Holes and sleeves for connection dowels, plus cast-in connection plates
  • Fixings for facade panels and cladding substructures
  • Internal voids for rainwater downpipes

Section size, column height, corbel levels and reinforcement layout are set for each building by the structural design. Rather than a fixed catalog of sizes, the loads and spans of your project drive the design.

Production

Columns are cast in steel molds adjusted to the project dimensions, once the reinforcement cage and cast-in parts are in place. A column is not demolded or shipped until the concrete has reached the required strength. Before casting, the position of reinforcement, cover and cast-in parts is checked, and concrete strength is tracked with test specimens. Plant production makes concrete quality, cover and dimensional tolerances far easier to control than on a construction site.

Erection

On site, columns are lifted by mobile crane into prepared socket (pocket) foundations. Once plumb and at the correct level, each column is temporarily braced and the socket gap is filled with high-strength grout or concrete. When the infill has gained sufficient strength, beams and roof elements are placed on top.

How it differs from a cast-in-place column

With a cast-in-place column, formwork, reinforcement and concreting all happen on site; every column means waiting for the forms to be set, poured and struck, and progress depends on the weather. A precast column is produced in the plant while foundation work continues on site, and is set in place quickly once it arrives. Working with the same molds and the same production routine also keeps dimensional and quality differences between columns to a minimum.

What we need for a quote

The site location, approximate building dimensions, column grid, building height and any overhead crane requirements are enough to get started. Final dimensions are confirmed by the structural design.

Advantages

  • Verifiable concrete quality and dimensional accuracy thanks to controlled plant production
  • Shorter construction time, as production runs in parallel with foundation works
  • Fast placement into socket foundations with minimal work on site
  • Corbels, dowel holes and cast-in parts prepared during production
  • Non-combustible concrete and a long service life
  • Durable surface with no painting or corrosion maintenance

Technical specifications

Dimensions, reinforcement and load capacity are set by structural design for each project; contact us for technical details.

Frequently asked questions

How are precast column dimensions determined?
The section, height, corbel levels and reinforcement are set in the structural design, taking into account building dimensions, spans, roof and snow loads, any overhead crane and the seismic zone of the site. That is why each column is designed for your project rather than picked from a standard size list.
How is a precast column connected to the foundation?
The most common method in industrial precast buildings is the socket (pocket) foundation. The column is lowered into the socket, set plumb, and the gap is filled with high-strength grout or concrete. Other connection details can be used where the project requires.
Can the columns carry overhead crane loads?
Yes, provided this is allowed for in the structural design. The corbels that support the crane beams are formed during column production, and crane loads are included in the column design. Crane capacity and rail level therefore need to be confirmed at the start of the project.
Are precast columns earthquake resistant?
Seismic performance depends more on design than on the material itself. Precast columns that are designed to the Turkish Building Earthquake Code, detailed with sound connections, and produced and erected according to their drawings are engineered to deliver the performance the code requires.

Projects using this product

Related content

Other products

All products

Facade and Floor Elements

Precast Facade Panel

A precast facade panel is a reinforced concrete wall unit made at the plant and fixed to the precast frame of an industrial building. It gives the building a durable, non-combustible envelope that goes up quickly.

Infrastructure Elements

Precast Concrete Pile

A precast concrete pile is a reinforced or prestressed foundation element made in the plant and driven into the ground on site. It carries building loads past weak upper soil layers down to firmer strata.

Perimeter and Protection Elements

Concrete Fence Post

A concrete fence post is a reinforced precast post set into the ground to carry chain-link mesh, barbed wire or panel fencing. It provides a durable, low-maintenance fence line around land, industrial sites, vineyards and orchards.