Skip to content
TR EN
Get a Quote 0424 236 25 40

BeamsProducts

Precast Beam

A precast beam is a horizontal precast concrete member that spans between columns and transfers roof, floor or crane loads to them.

Precast Beam

What is a precast beam?

A precast beam is a horizontal load-bearing member produced in the plant and placed on site onto column corbels or column heads. Beams tie the columns together, complete the structural frame and carry the loads above them down to the columns.

Its role in an industrial building

In an industrial building, a beam's job depends on where it sits and what it carries. The industry typically groups beams by function as follows:

Beam functionRole in the building
Tie (frame) beamConnects the columns and holds the building together in the longitudinal direction
Floor beamCarries the floors of offices, platforms or mezzanines
Crane beamSupports the overhead crane rail and transfers crane loads to the columns
Facade beamProvides support and fixing surfaces for facade cladding and window bands

Which beam types your project needs, and the scope of production, are confirmed together during the project review.

Section options

Precast beams can be designed with rectangular, I, T, inverted T or L sections. Inverted T and L sections are common where floor units will bear on the beam. Across the industry, beams are produced either as conventionally reinforced or as prestressed members. In pre-tensioned production, steel strands are tensioned before casting and released once the concrete has gained sufficient strength, pre-compressing the member so that longer spans and slimmer sections become possible. The method, section dimensions and reinforcement layout are set by the structural design.

Production and quality

Beams are cast in project-specific molds once reinforcement, connection sleeves and cast-in parts are in place. The plant environment allows concrete mix, cover and dimensions to be checked with the same care on every element. Each element is marked according to its position in the erection plan before dispatch.

Erection and connections

On site, beams are lifted by crane and set onto the column corbels. An elastomeric (neoprene) bearing pad is usually placed at the support; the beam is located by dowels projecting from the column, and the dowel holes are grouted to complete the connection. Connection details are designed to the rules the earthquake code sets for precast reinforced concrete buildings.

Choosing the right beam

The main factors in beam selection are the span to be covered, the loads to be carried, column spacing, building height and transport conditions. Very long, heavy beams may call for larger cranes and special transport, so spans and column grids are planned together with production and erection constraints in mind. If there will be an overhead crane, a mezzanine or heavy services, flagging them at the start lets the beams be designed for those loads and avoids the need for strengthening later.

Advantages

  • Section options capable of spanning wide bays
  • Dimensional accuracy from controlled plant production
  • Fast erection that reduces formwork and scaffolding on site
  • A production schedule far less exposed to the weather
  • Non-combustible, long-lasting concrete structure
  • Connection sleeves and cast-in parts prepared during production

Technical specifications

Dimensions, reinforcement and load capacity are set by structural design for each project; contact us for technical details.

Frequently asked questions

What spans can a precast beam cover?
The achievable span depends on the beam section, whether it is prestressed, the loads it carries, and transport and erection constraints. The right length and section for your project are set by structural calculation; at quotation stage, simply share the spans you need.
What is the difference between reinforced and prestressed beams?
In a reinforced concrete beam, the reinforcement starts working as the load is applied. In a prestressed beam, steel strands are tensioned in advance to pre-compress the member. This improves crack control and allows a longer span or a slimmer section for the same load.
How are beams connected to the columns?
The beam is seated on an elastomeric bearing pad on the column corbel and located by dowels projecting from the column. The dowel holes are then grouted to complete the connection. Other connection details can be used where the project requires.
What information is needed to produce beams?
We need the structural design or, at a minimum, the building dimensions, column grid, floor and crane details, and the site location. If there is no structural design yet, how the design stage will proceed is planned together during the site survey and initial meeting.

Projects using this product

Related content

Other products

All products

Facade and Floor Elements

Precast Facade Panel

A precast facade panel is a reinforced concrete wall unit made at the plant and fixed to the precast frame of an industrial building. It gives the building a durable, non-combustible envelope that goes up quickly.

Infrastructure Elements

Precast Concrete Pile

A precast concrete pile is a reinforced or prestressed foundation element made in the plant and driven into the ground on site. It carries building loads past weak upper soil layers down to firmer strata.

Perimeter and Protection Elements

Concrete Fence Post

A concrete fence post is a reinforced precast post set into the ground to carry chain-link mesh, barbed wire or panel fencing. It provides a durable, low-maintenance fence line around land, industrial sites, vineyards and orchards.